Part Details | AMMETER
6625-00-019-3421 An instrument which measures electric current and is calibrated and marked in amperes or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. For current detecting type of devices, see GALVANOMETER.
Alternate Parts: HS3Z0102AMP, HS3Z0-1-0-2AMP, 1816976, 1816976, 6625-00-019-3421, 00-019-3421, 6625000193421, 000193421
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | MAY 15, 1968 | 00-019-3421 | 16450 ( AMMETER ) |
REFERENCE DRAWINGS & PICTURES
THREE HOLE/STUD BOLT CIRCLE
ROUND FLUSH MTG
Cross Reference | NSN 6625-00-019-3421
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| HS3Z0-1-0-2AMP | 33005 | JEWELL INSTRUMENTS, LLCDBA MODUTEC |
| 1816976 | 21877 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NAVAL AND MARINE SYSTEMS |
| 1816976 | 03956 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NAVIGATION AND MARITIME SYSTEMS |
Technical Data | NSN 6625-00-019-3421
| Characteristic | Specifications |
|---|---|
| INSTALLATION DESIGN | PANEL |
| INDICATOR TYPE | DIAL W/POINTER |
| MOVEMENT TYPE | MOVING COIL, PERMANENT MAGNET |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 SOLDER LUG |
| SENSITIVITY RATING | 50.0 MILLIVOLTS |
| CIRCUIT CURRENT FOR WHICH DESIGNED | DC |
| STYLE DESIGNATOR | ROUND FLUSH MTG |
| METER BODY DIAMETER BEHIND MOUNTING FLANGE | 2.680 INCHES NOMINAL |
| METER DEPTH BEHIND MOUNTING FLANGE | 1.660 INCHES NOMINAL |
| OVERALL DIAMETER | 3.510 INCHES NOMINAL |
| OVERALL LENGTH | 2.850 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE |
| MOUNTING HOLE DIAMETER | 0.150 INCHES NOMINAL |
| MOUNTING ARRANGEMENT STYLE | THREE HOLE/STUD BOLT CIRCLE |
| MOUNTING BOLT CIRCLE DIAMETER | 3.160 INCHES NOMINAL |
| PANEL FOR WHICH DESIGNED | B$C |
| CIRCUIT CONSTRUCTION TYPE | NONELECTRONIC |
| MATERIAL | STEEL |
| NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
| ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND VIBRATION RESISTANT |
| SPECIAL MARKINGS | AMPERES DIRECT CURRENT ON FACE OF DIAL SCALE |
| FEATURES PROVIDED | MAGNETIC SHIELD AND ZERO ADJUSTER |
| SPECIAL FEATURES | RUGGEDIZED |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| FSC APPLICATION DATA | TEST SET,ELECT. EQUIP. |