Part Details | ULTRASONIC TEST TRANSDUCER
6635-01-353-7788 An item designed to convert electrical signals into mechanical vibrations or ultrasound beams. These signals are passed through a material and are reflected and scattered by any discontinuities (flaws) back to the receiving unit where they are reconverted to electrical signals and amplified for processing on an indicator for interpretation. See also TRANSDUCER, SUPERSONIC TEST.
Alternate Parts: 126660, 126-660, 125, 125, GRD1002HR, GRD-1002-HR, 6635-01-353-7788, 01-353-7788, 6635013537788, 013537788
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | FEB 16, 1992 | 01-353-7788 | 45466 ( TRANSDUCER, ULTRASONIC TEST ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6635-01-353-7788
Part Number | Cage Code | Manufacturer |
---|---|---|
126-660 | 52039 | AGFA NDT INCKRAUTKRAMER ULTRASONICS DIV |
125 | 61100 | NDT ENGINEERING CORPORATION |
125 | 1KY21 | OLYMPUS AMERICA INC. |
GRD-1002-HR | 43735 | TECHNISONIC RESEARCH INC |
Technical Data | NSN 6635-01-353-7788
Characteristic | Specifications |
---|---|
TRANSMITTER FREQUENCY RATING | 10000.0 KILOHERTZ NOMINAL |
OVERALL DIAMETER | 0.250 INCHES NOMINAL |
SPECIAL FEATURES | DESIGNED FOR THICKNESS GAUGING AND FLAW DETECTION OF THIN MATERIALS |