Part Details | RADIACMETER
6665-00-444-4715 An item specifically designed to detect and measure radioactive energy; indicates directly. It may or may not include the function of a radiac computer.
Alternate Parts: 493, 6665-00-444-4715, 00-444-4715, 6665004444715, 004444715
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | DEC 23, 1970 | 00-444-4715 | 07833 ( RADIACMETER ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6665-00-444-4715
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 493 | 63060 | HEICO OHMITE LLCDBA OHMITE MFG CO INC |
Technical Data | NSN 6665-00-444-4715
| Characteristic | Specifications |
|---|---|
| RADIATION RANGE PER HOUR | +0.0 TO +50.0 MILLIROENTGENS |
| INDICATOR TYPE | CJ ANY ACCEPTABLE |
| DETECTING ELEMENT TYPE | E ANY ACCEPTABLE |
| PORTABILITY | PORTABLE |
| CARRYING CASE | NOT PROVIDED |
| CASE MATERIAL | ALUMINUM |
| OVERALL LENGTH | 8.750 INCHES NOMINAL |
| OVERALL WIDTH | 4.500 INCHES NOMINAL |
| OVERALL HEIGHT | 6.630 INCHES NOMINAL |
| MOUNTING METHOD | PORTABLE |
| SPECIAL FEATURES | RADIATION DETECTED DEPENDS ON DETECTOR USED; STANDARD PROBE (DETECTOR) IS P/N 493-50 BUT ACCEPTS ALL VICTOREEN GM PROBES; POWER 2 NEDA 13 D BATTERY CELLS; CONTROLS SINGLE 5 POSITION FUNCTION SWITCH INCLUDING BATTERY CHECK POSITION; WEIGHT 3.5 LBS; ACCURACY WITHIN 10% OF READING FULL SCALE INDICATION ON ANY RANGE; OPERATING RANGE 0-300, 3000 AND 30,000 CPM CORRESPONDING TO 0-0.5, 5 AND 50 MR/H |
| SUPPLEMENTARY FEATURES | UTILITY SURVEY METER |