Part Details | FLOW RATE INDICATING METER
6680-00-057-4254 An instrument for measuring the rate of flow of a fluid through a pipeline. This measurement is indicated on a graduated scale either by means of a float confined in a tube, or pointer connected to a vane, or piston and spring or the like. Excludes METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
Alternate Parts: 1110VHMSB, 1110-VH-MSB, 1110VHMSB, 1110-VH-MSB, 6680-00-057-4254, 00-057-4254, 6680000574254, 000574254
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | JAN 01, 1963 | 00-057-4254 | 38346 ( METER, FLOW RATE INDICATING ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-00-057-4254
Part Number | Cage Code | Manufacturer |
---|---|---|
1110-VH-MSB | 4ZW64 | BROOKS INSTRUMENT LLC |
1110-VH-MSB | 91556 | EMERSON ELECTRIC CODBA BROOKS INSTRUMENT DIVISION |
Technical Data | NSN 6680-00-057-4254
Characteristic | Specifications |
---|---|
DESIGN TYPE | CASE |
SCALE QUANTITY | 1 |
DIAL SCALE MARKING RANGE | P0.0/P250.0 |
DIAL SCALE REFERENCE POINTER | NOT INCLUDED |
METER TYPE | FLOAT |
OVERALL LENGTH | 22.000 INCHES NOMINAL |
INTEGRAL PULSATION DAMPENER | NOT INCLUDED |
INLET CONNECTION TYPE | THREADED |
INLET CONNECTION POSITION FOR WHICH DESIGNED | HORIZONTAL |
OUTLET CONNECTION TYPE | THREADED |
OUTLET CONNECTION POSITION FOR WHICH DESIGNED | HORIZONTAL |
INTEGRAL RELIEF VALVE | NOT INCLUDED |
INTEGRAL HEAT SOURCE | NOT INCLUDED |
ALARM SIGNAL | NOT INCLUDED |
CONSTRUCTION | HP ANY ACCEPTABLE |
BASE | NOT INCLUDED |
CARRYING HANDLE | NOT INCLUDED |
METERING TUBE QUANTITY | 1 |
TUBE MATERIAL | GLASS |
SCALE TYPE | MILLIMETER REFERENCE READING |
MAXIMUM WATER CAPACITY IN GALLONS PER MINUTE | 4.04 |
DIAL SCALE SMALLEST INCREMENT | 2MM |
FLOAT QUANTITY | 1 |
FLOAT MATERIAL | STEEL |
SPINNING FLOAT | NOT INCLUDED |
FLOAT TYPE | GUIDED |
GUIDE TYPE | BEADED TUBE |
UNIT TYPE | MOUNTED |
MOUNTING METHOD | FLUSH PANEL |
INLET CONNECTION SIZE | 0.750 IN. NPT |
INLET CONNECTION DEVICE TYPE | STATIONARY |
OUTLET CONNECTION SIZE | 0.750 IN. NPT |
OUTLET CONNECTION DEVICE TYPE | STATIONARY |
MAXIMUM WORKING PRESSURE | 240.0 POUNDS PER SQUARE INCH |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY SERIAL NO. 6203-33610/3 |