Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER


6680-00-068-0302 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.

Alternate Parts: FS81124, FS8112-4, 6680-00-068-0302, 00-068-0302, 6680000680302, 000680302

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66JAN 01, 196300-068-030208249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE )
REFERENCE DRAWINGS & PICTURES

Cross Reference | NSN 6680-00-068-0302
Part Number Cage Code Manufacturer
FS8112-404577CARLETON TECHNOLOGIES INC

Technical Data | NSN 6680-00-068-0302
Characteristic Specifications
MEDIA FOR WHICH DESIGNEDB$DBD
PRESSURE TYPE MEDIUM
MAXIMUM DIFFERENTIAL PRESSURE15.0 PSI
SCALE PRESENTATION RANGEMINUS 10 TO 0 TO PLUS 15 RANGE OF NUMERICAL MARKINGS
SMALLEST INCREMENT INDICATED0.200
SCALE INSCRIPTION/BACKGROUND COLORWHITE MARKINGS ON BLACK BACKGROUND
TOTALIZING INTEGRATOR REGISTER NOT INCLUDED
CASE MATERIAL ALUMINUM
CASE SHAPE RECTANGULAR
MOUNTING TYPED ANY ACCEPTABLE
DEPTH8.688 INCHES NOMINAL
HEIGHT6.500 INCHES NOMINAL
WIDTH7.625 INCHES NOMINAL
INLET CONNECTION SIZE1/2 IN.-14 THD NPT
OUTLET CONNECTION SIZE1/4 IN.-18 THD NPT