Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER
6680-00-351-8390 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
Alternate Parts: 07ABXXX0491A5BXXXX01, 6680-00-351-8390, 00-351-8390, 6680003518390, 003518390
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | MAR 31, 1971 | 00-351-8390 | 08249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-00-351-8390
Part Number | Cage Code | Manufacturer |
---|---|---|
07ABXXX0491A5BXXXX01 | 05991 | CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS |
Technical Data | NSN 6680-00-351-8390
Characteristic | Specifications |
---|---|
MEDIA FOR WHICH DESIGNED | LIQUID |
PRESSURE TYPE | K$J |
MAXIMUM DIFFERENTIAL PRESSURE | 49.1 IN. OF WATER COLUMN |
SCALE PRESENTATION RANGE | 0 TO 49.1 RANGE OF NUMERICAL MARKINGS |
SCALE INSCRIPTION/BACKGROUND COLOR | BLACK MARKINGS ON WHITE BACKGROUND |
TOTALIZING INTEGRATOR REGISTER | NOT INCLUDED |
CASE MATERIAL | ALUMINUM, CAST |
CASE SHAPE | ROUND |
MOUNTING TYPE | D ANY ACCEPTABLE |
DEPTH | 4.656 INCHES NOMINAL |
DIAMETER | 6.500 INCHES NOMINAL |
INLET CONNECTION SIZE | 1/4 IN. 18 THD NPT |
OUTLET CONNECTION SIZE | 1/4 IN. 18 THD NPT |
ACCESSORY COMPONENTS AND QUANTITY | BERYLLIUM COPPER SENSOR W/FORGED BRASS HOUSING,1 |
SPECIAL FEATURES | 6.000 IN. DIA DIAL |
CRITICALITY CODE JUSTIFICATION | ACPYY$$AFEAT |